        The process of gradually forming a conductive path on the surface of a solid insulating material under the combined action of an electric field and an electrolyte is called leakage tracking. The ability of the surface of the insulating material to resist tracking is called tracking resistance.

        Test purposes

        The tracking resistance test is mainly a test to simulate whether the conductive substances deposited on the surface of the insulating material of live parts of different polarities caused by household appliances in actual use cause the creeping, breakdown short circuit and fire hazard of the surface of the insulating material. During the use of electrical products, due to environmental pollution, there are dirt and moisture on the surface of the insulating material, which causes electrical leakage, which leads to corrosion and damages the insulating performance. The test specified in this standard is an accelerated test that simulates extremely harsh conditions to check whether the insulation material will form a trace of leakage, which can distinguish the ability of the solid insulation material to resist tracking in a short time and ensure that the product is under specific environmental conditions. Safe to use.

        Scope of application

        It is suitable for the research, production and quality inspection departments of lighting equipment, low-voltage electrical appliances, household appliances, machine tool appliances, motors, power tools, electronic instruments, electrical instruments, and information technology equipment. It is also suitable for insulating materials, engineering plastics, electrical connectors, Accessories industry.

        Method Standard

        For details, see "GB/T 4207-2012 Solid insulating materials under wet conditions compared to the tracking index and tracking resistance index measurement method"

        Test analysis

        The factors influencing this test can be summarized as follows:

        Sample pretreatment

        As the standard requires that the surface of the sample should be clean, and the sample will inevitably have release agent, oil, dust and other contaminants after the manufacturing, transportation, transfer and other links to the final test. Therefore, the sample surface must be cleaned. At present, there are several cleaning methods used for this test in China:

        a. Distilled water b. Dry cotton ball c. Eraser d. Anhydrous alcohol. And the cleaning procedures are different. Distilled water will change the humidity of the surface of the sample. Wiping with a dry cotton ball is more difficult to remove grease. Wiping with a rubber eraser will change the true condition of the sample. Anhydrous alcohol can both clean the grease and volatize on its own, which is ideal. Improper cleaning methods have a greater impact on the test results.

        Flatness of test surface, test size and thickness

        If the test surface is uneven or has scratches, it will affect the test results and cause the test results to deviate. The size of the sample does not meet 15mm × 15mm × 3mm. During the test, the electrolyte may flow out from the edge of the sample, resulting in a shortening of the combined action time of the electric field and the electrolyte. The thickness is less than 3mm, and the heat capacity of the material becomes smaller, resulting in faster heat dissipation, resulting in The test results are affected.

        The resistivity and purity of the electrolyte

        The resistivity and purity of the electrolyte are two important factors in the tracking test. Because of the conductivity meters commonly used for platinum-black conductivity electrodes, their platinum-black conductivity electrodes are prone to inerting, which leads to inaccurate resistivity testing. So how to use a simple method to determine the performance of platinum black conductivity electrode is good and accurate measurement

        The resistivity of the test solution is the key i. The problem of the solution containing impurities is usually easily overlooked, mainly due to the impureness of the distilled water used to prepare the electrolyte.

        Relative tracking index and tracking resistance index

        Relative Tracking Index (CTI): The highest voltage value of five test samples that can withstand the test process of 50 drops without generating tracking tracking failure and continuous flame. It also includes a description of the characteristics of the material when 100 drops are tested.

        (PTI): Five test samples can withstand the test process of 50 drops without generating tracking voltage failure and continuous flame test voltage value.


        Online consultation

        Online consultation

        Recommend
        • Australian RCM certification

          Australian RCM certification

          Australian RCM certification

        • Label printer ANATEL certification

          Label printer ANATEL certification

          Label printers entering the Brazilian market, ANATEL certification is an essential passport! It is the recognition of the Brazilian Telecommunications Authority for the safety and compliance of electronic products, without which products cannot be legally sold.

        • Label printer SRRC certification

          Label printer SRRC certification

          SRRC certification is not only a guarantee of product compliance, but also a key to opening up the market.

        Tracking

        The process of gradually forming a conductive path on the surface of a solid insulating material under the combined action of an electric field and an electrolyte is called leakage tracking. The ability of the surface of the insulating material to resist tracking is called tracking resistance.

        Get a quote
        主站蜘蛛池模板: 欧美a级欧美1级a大片| 亚洲成年网站在线观看| 成人国产亚洲精品天堂AV| 亚洲精品精华液| 日韩一区二区三区av| 日韩精品视频免费福利在线观看 | 亚洲精品色午夜无码专区日韩| 日韩精品在线二区三区| 久久精品无码专区东京热| 国产精品户外野外| 新激情五月天| 国语憿情少妇无码av| 中国老太婆bb无套内射| 欧美顶级metart裸体全部自慰| 女人毛片女人毛片高清| 久久精品国产亚洲av麻豆软件| 色婷婷久| 9WW6CC视频| 2020国产成人精品视频| 欧洲多毛裸体xxxxx| 香蕉国产人午夜视频在线观看| 免费特黄一区二区三区视频一| 最新国产AV最新国产在钱| 三级三级久久三级久久| 国产AV中文字幕| 久久99国产精品尤物| 成人久久精品一区二区三区| 亚洲国产另类久久久精品黑人 | 91天堂| 成人激情视频一区二区三区| 97人人超碰国产精品最新| 临海市| 精品综合久久久久久97| 999无码精品亚洲精品日韩人妻无码| 国产91小视频在线观看| 中文字幕一区在线观看视频| 二区三区国产在线观看| 精品视频专区| av激情综合网| 国产精品自线在线播放| 99精品国产在热久久无毒不卡 |